GlucoRx HCT Meter is specifically for Type 1 diabetics is a quality, unique multiparameter machine. It contains Haematocrit Correcton Technology whcih provides a complete health check by measuring blood glucose, ketone and haematocrit.
GlucoRx HCT Glucose test strips use advanced enzyme technology with 2+ 2 (AC and DC) Bio Signal. The AC signal works to provide the haematocrit result and the DC calculates the glucose. The meter then corrects the glucose level according to the haematocrit value for enhanced accuracy in the self-management of diabetes.
METER FUNCTIONALITY GlucoRx HCT Meter
Measures Blood glucose, Haematocrit, Ketone
Test Strips & Lancets Uses GlucoRx HCT Glucose Test Strips and GlucoRx HCT Ketone Test Strips. Also GlucoRx Lancets.
Accuracy Exceeds latest ISO 15197:2013 system accuracy requirements
System Haematocrit 10 – 70% (ketone strips); 0 – 70% (glucose strips)
Blood sample 1.0µL for both Glucose & Ketone tests
Reaction time 5 seconds for Glucose test, up to 10 seconds for Ketone test.
Measurement range mmol/L fixed. 0.5 to 35 mmol/L for Glucose test, 0.1~8.0 mmol/L for Ketone test.
Measuring modes Gen – any time of day, regardless of time since last meal. AC – No food intake for at least 8 hours. PC – 2 hours after a meal. Control solution test (QC) auto tagged.
Accomodates AST On fingertips and palm only when Ketone testing.
Strip ejection for safe disposal Yes
Discreet testing Buzzer can be disabled
Ketone warning >15mmol/L
Alarms Four
Day averages function 7-, 14-, 21-, 28-, 60- & 90- day averages
Software PC download facility; Eclipse Telehealth and Diasend compatibility pending.
Large, non-deletable memory 1000 readings – suitable for Diabetic Drivers complying with DVLA guidelines
Dimensions 96 (L) x 61 (W) x 26 (H) mm
Screen size 50 x 35 mm
Product weight (including batteries) 67.2g
Power (non-rechargeable) 2x AAA
Other Special features Backlit screen, auto switch-off after 3 minutes without action and temperature warning.
Operating conditions 10°C to 40°C (50°F to 104°F), below 85% R.H. (non-condensing)
Meter Storage/Transportation conditions -20°C to 60°C (-4°F to 140°F), below 95% R.H.
Strip Storage/Transportation conditions 2°C to 32°C (35.6°F to 89.6°F) for glucose test strip and 2°C to 30°C, (35.6°F to 86°F) for ?-ketone test strip, below 85% R.H.
Features
• Results meet system accuracy requirements of ISO 15197:2015
• Haematocrit Correction Technology for increased accuracy in self-management of blood glucose
• 10 - 70% haematocrit range makes this suitable for use on newborns and pregnant ladies
• Automatically identifies control solution testing
• 1.0?L blood volume required and results in 5 seconds
• Strip ejector, AST, AC/PC meal markers, day averages, 4 alarms, discreet testing and ketone warning
• 1000 non-deletable result memory
• Compatible with Diasend for easy viewing of result
Brand | Glucorx |